Magic Chef CGR3725ADS Spezifikationen Seite 59

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 63
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 58
©2004 Maytag Services 16023522 C–11
Conversion Instructions (Models AGR5712AD*, CG34800AD*,
CGR3725AD*, MGR5751AD*, MGR5752AD*, PGR5720LD*)
3
    
a. The approximate length of the flame of oven burner is
a 1/2 inch distinct inner blue flame, figure 8.
b. Oven burner flame can be checked as follows:
1. Yellow flame on burner - open burner air shutter to
the widest opening that will not cause the flame to lift
or blow off the burner when cold. (See #2 on figure
9.)
2. Distinct blue flame but lifting - close burner air
shutter to the point where it will not cause the flame
to lift or blow off the burner when cold. (See #2 on
figure 9.)
c. The oven burner air shutter adjustment is the same on
ranges with a gas pilot or electric ignition.
d. Sealed burner adjustment. Adjust the air shutter for the
appropriate gas according to figure 10.
4. Remove the surface burner orifice hood with a ² (12.7
mm) socket wrench counter-clockwise.
: Save all natural orifice hoods that are
removed.
5. Place the corresponding orifice hood on the burner
fitting according to figure 6. Turn the orifice hood
clockwise by hand approximately one turn. Tighten the
orifice hood clockwise with a ² socket wrench
approximately 2 turns.
6. Replace the burner assembly in the main top and
rotate one-eighth turn clockwise using the burner
wrench until the burner locks in place with the igniter
aligned with the reference mark on the main top.
7. Repeat steps 3 through 6 until all orifice hoods have
been changed.
 
Replace burner assembly in main top and rotate
approximately one-eighth turn clockwise using burner
wrench until burner locks into position with ignitor aligned
with reference mark on main top.




 
3
LOCK
SCREW
AIR SHUTTER
2
1
ORIFICE
HOOD
ORIFICE HOOD
AIR SHUTTER
NATURAL POSITION
AIR SHUTTER
LP POSITION
7.2K BTU NATURAL (BLUE)
REPLACE WITH ORIFICE (BLUE)
STAMPED .0310 FOR LP
9.2K BTU NATURAL (NO COLOR)
REPLACE WITH ORIFICE (NO COLOR)
STAMPED .0335 FOR LP
12K BTU NATURAL (RED)
REPLACE WITH ORIFICE (RED)
STAMPED .0350 FOR LP
9.2K BTU NATURAL (NO COLOR)
REPLACE WITH ORIFICE (NO COLOR)
STAMPED .0335 FOR LP
FRONTOFMAINTOP
ART. #9215-250-1
Seitenansicht 58